Important Note: The DBU is a database utility
program that you can use to manipulate data directly. Great care should be taken when
working in the DBU. You may cause irreparable damage, delete or change data if you do not
know what you are doing. Make a backup before you open the DBU. Please follow the
instructions very carefully. If you are unsure of any instruction please do not hesitate
to contact Otomys directly at (012) 348 4071. Otomys will not be held accountable for any
data loss or corruption. |
| How to discharge all hospital cases simultaneously |
Exit from of Microvet on all the computers Make a backup Do these steps on the file server Click on START Click on PROGRAMS Click on ACCESSORIES (only for windows ME/XP/NT
and 2000) Click on MS-DOS PROMPT or COMMAND PROMT (From now on you will not be able to use your
mouse, use the Enter key and the arrows on your keyboard.) Type the following: CD\MFW5 DBU F2 DATABASE Open TRANSAC.DBF OK F6 REPLACE Select the field
TRCOMPLETE Replace with
.T. OK ESC ESC EXIT TO DOS Y DEL *.IDX EXIT Start Microvet The program will automatically start to re-index A message may appear: File is not marked
with a code page Click on Windows The selection will go to Windows ANSI Click on Select Log in |